Annex A 7.5: Protecting Against Physical Environmental Threats

Annex a 7.5: protecting against physical environmental threats requirement means you must identify environmental hazards that could impact information processing facilities (fire, flood, power loss, HVAC failure, water leaks), implement proportional physical safeguards, and keep evidence that those safeguards work. Operationalize it by scoping in-scope sites, documenting risks and controls, testing alarms/monitoring, and retaining maintenance and incident records.

Key takeaways:

  • Treat 7.5 as an engineering-and-evidence control: risk assessment, protective measures, and proof of operation.
  • Auditors look for completeness (all in-scope sites and critical rooms) and operational records (tests, maintenance, alerts, exceptions).
  • Start with a facility-by-facility threat model and a control-to-evidence map you can run on a schedule.

Annex A 7.5 sits in the physical controls domain and focuses on environmental threats to the places where you process or house information, including offices, data rooms, wiring closets, and any third-party colocation spaces you rely on. For most service organizations, gaps are rarely about intent; they are about scope misses (someone forgets the “small” network closet), weak ownership (facilities vs. security vs. IT), and thin evidence (controls exist, but nobody can show they were inspected, tested, or maintained).

From an ISO 27001 operator perspective, you need three things: (1) a clear definition of which facilities are in-scope for your ISMS, (2) environmental threat risks assessed and treated with appropriate safeguards, and (3) repeatable proof that those safeguards are operating as designed. The fastest path is to build a single control narrative that ties together facilities standards, preventative maintenance, monitoring/alerting, and incident handling for environmental events, then schedule evidence capture. The control expectation is described at a high level in ISO/IEC 27001 materials and public summaries of Annex A controls (ISO/IEC 27001 overview; ISMS.online Annex A control index).

Regulatory text

Provided excerpt: “ISO/IEC 27001:2022 Annex A control 7.5 implementation expectation (Protecting Against Physical Environmental Threats).” (ISO/IEC 27001 overview; ISMS.online Annex A control index)

Operator meaning (what you must do):
You must protect information processing facilities from environmental events that could cause loss of confidentiality, integrity, or availability. Practically, that means you:

  1. identify credible physical/environmental hazards for each in-scope location,
  2. implement protective and detective measures appropriate to the risk, and
  3. maintain evidence that measures are installed, maintained, and tested on a defined cadence.
    This is a “show your work” control: auditors will accept different safeguards by site, but they will not accept missing scope, unclear ownership, or no maintenance/testing records. (ISO/IEC 27001 overview; ISMS.online Annex A control index)

Plain-English interpretation of the requirement

Annex a 7.5: protecting against physical environmental threats requirement is about preventing outages and damage from the building environment. The threats are mundane and common: water leaks above a rack, a stuck HVAC unit overheating a closet, construction dust in an office network room, a localized fire, or unstable power damaging equipment. The control expects you to treat these as information security risks because environmental failures become security incidents when systems go down, logs are lost, or equipment is destroyed. (ISO/IEC 27001 overview; ISMS.online Annex A control index)

Who it applies to (entity and operational context)

Applies to: service organizations implementing ISO/IEC 27001 where availability and integrity of systems matter for customers, regulators, or internal operations. (ISO/IEC 27001 overview)

Operational contexts that are usually in-scope:

  • Corporate offices with production endpoints, identity infrastructure, or sensitive paper records
  • On-prem server rooms, MDF/IDF closets, lab spaces, and comms rooms
  • Colocation cages and managed data centers (even if the third party “runs” the building)
  • Warehouses or operational sites with IoT, OT-like components, badge systems, or cameras that support security objectives

Common scoping pitfall: teams scope only the “data center” and miss smaller closets, records rooms, and leased suites. Those spaces often have the weakest environmental controls and become audit findings.

What you actually need to do (step-by-step)

1) Set scope and ownership (so the control can run)

  • Create an in-scope facilities register tied to your ISMS scope statement: sites, floors/suites, critical rooms (server room, comms closet), and what information assets are supported there.
  • Assign control owners: typically Facilities owns building systems and maintenance; Security/GRC owns requirements and evidence; IT owns equipment placement and rack/room standards.
  • Define “information processing facilities” for your org in a one-page standard so there’s no debate during audits. (ISO/IEC 27001 overview)

2) Perform an environmental threat assessment per site

For each site/critical room, document:

  • Threats: fire/smoke, water leak/flood, HVAC failure/overheating, humidity, dust, power outage/surge, building access during emergencies, nearby construction, seismic events where relevant.
  • Vulnerabilities: equipment under sprinkler lines, no leak detection, single HVAC unit, no UPS, no temperature monitoring, poor housekeeping/cable management blocking airflow.
  • Impact: system downtime, loss of audit logs, loss of customer data availability, inability to meet incident response obligations.
  • Risk treatment decision: mitigate/transfer/accept, with approvals and compensating controls.

Keep it practical: a table per site is enough if it clearly links threats to controls and owners.

3) Implement minimum environmental protections (baseline + risk-based add-ons)

Build a baseline that applies to all critical rooms, then add controls for higher-risk sites.

Baseline controls (examples you can tailor):

  • Power protection: UPS for critical network/security equipment; surge protection; documented safe shutdown behavior.
  • Temperature/humidity monitoring: sensors with alerting to on-call distribution.
  • Water exposure reduction: keep equipment off floors where feasible; avoid placement under known water sources; define a response procedure for leaks.
  • Fire protection readiness: clear egress, no blocked vents, housekeeping standards; awareness of building fire detection and response procedures.
  • Physical layout controls: racks/cabinets, cable management, no storage of combustibles in comms rooms, controlled keys/access.

Risk-based add-ons (apply where justified):

  • Leak detection sensors in rooms under plumbing or roof lines
  • Redundant HVAC or portable backup cooling plan
  • Generator or alternate power arrangements (if uptime needs justify it)
  • Relocation of equipment to reduce exposure (often the cheapest risk reduction)

This control is satisfied by “appropriate measures,” not a single mandated technology list. Your job is to show that your measures match your risk assessment. (ISO/IEC 27001 overview; ISMS.online Annex A control index)

4) Operationalize monitoring, maintenance, and testing

Audits often fail here because controls exist but no one can prove they ran.

Minimum operational elements:

  • Preventive maintenance program for UPS units, sensors, HVAC servicing in critical rooms (as applicable), and any suppression/detection equipment under your responsibility.
  • Alert handling workflow: who gets alerts, expected response steps, and how you record and close events (ticketing system entries work well).
  • Periodic tests: alarm tests, sensor checks, UPS self-tests or battery checks, and restoration steps if an alert indicates a true issue.
  • Exception process: document any sites where you cannot meet baseline (leased space constraints) and record compensating controls and acceptance approvals.

5) Map control operation to recurring evidence capture

Create a simple “control-to-evidence schedule” so you can produce proof on demand. This is explicitly aligned with the recommended approach to map 7.5 to documented control operation and recurring evidence capture. (ISO/IEC 27001 overview; ISMS.online Annex A control index)

If you run Daydream for compliance operations, treat 7.5 like a recurring evidence control: define owners, evidence types, collection frequency, and a single source of truth for artifacts so your audit prep is retrieval, not reinvention.

Required evidence and artifacts to retain

Keep artifacts that prove: (a) you assessed risk, (b) you implemented safeguards, (c) you maintain and test them, and (d) you respond to events.

Evidence checklist (practical):

  • Facilities register (in-scope sites and critical rooms)
  • Environmental threat/risk assessments per site with treatment decisions and approvals
  • Photos or diagrams of critical rooms (showing placement away from obvious hazards)
  • Monitoring configuration evidence (sensor inventory, alert routes, on-call list)
  • Maintenance logs and service records (UPS, sensors, HVAC servicing for critical rooms where you own it)
  • Test records (alarm/sensor tests, UPS tests)
  • Incident/ticket records for environmental alerts (leaks, overheating, power events) and post-incident reviews
  • Third-party attestations where facilities are operated by a colocation/provider, plus your review notes and any gaps tracked

Common exam/audit questions and hangups

Auditors and certification bodies typically probe for these gaps:

  • Scope: “Which facilities are in-scope, and how did you decide?”
  • Completeness: “Did you include closets, records rooms, and remote offices?”
  • Risk linkage: “Show me how your risk assessment drove the selected controls.”
  • Operation: “Prove monitoring is active and alerts are handled.”
  • Maintenance: “Show maintenance/service history and who owns it.”
  • Third party reliance: “If this is a colocation site, what did you do beyond trusting them?”

Hangup to expect: facilities teams often keep records in email threads or vendor portals. Pull those into an auditable repository with consistent naming and dates.

Frequent implementation mistakes and how to avoid them

  1. Treating 7.5 as “Facilities has it.”
    Fix: write a short RACI and require evidence handoffs into your ISMS repository.

  2. One risk assessment for “HQ” only.
    Fix: do per-site, per-critical-room assessment. A tiny closet can carry high availability impact.

  3. Buying sensors without an alert workflow.
    Fix: require tickets for alerts, assign on-call ownership, and test that alerts reach humans.

  4. No exception handling for leased spaces.
    Fix: document constraints, compensating controls, and formal risk acceptance.

  5. Third-party data center assumptions.
    Fix: request relevant documentation and track gaps as supplier risks; map dependencies to your BCP/IR plans.

Enforcement context and risk implications

No public enforcement cases were provided in the source catalog for this control, and ISO 27001 itself is a certifiable standard rather than a regulator. Your real risk is commercial and operational: environmental failures drive outages, data loss, and missed customer commitments. For ISO audits, the most common “penalty” is a nonconformity that can delay or jeopardize certification if unaddressed. (ISO/IEC 27001 overview)

Practical 30/60/90-day execution plan

First 30 days (stabilize scope + baseline)

  • Build the in-scope facilities and critical room register.
  • Assign owners and publish a short physical environmental threats standard.
  • Perform a fast environmental walk-through for each critical room and capture photos and obvious hazards.
  • Stand up an evidence folder structure and naming convention so artifacts don’t scatter.

By 60 days (risk assessment + controls operating)

  • Complete site/room environmental threat assessments and treatment decisions.
  • Implement baseline controls where missing (monitoring, housekeeping standards, placement fixes).
  • Configure alert routing and ticketing workflow for environmental alerts.
  • Collect first round of maintenance records and confirm who provides what (Facilities, IT, third parties).

By 90 days (prove repeatability)

  • Run at least one operational cycle: tests performed, alerts handled, issues tracked to closure.
  • Complete exception documentation and formal risk acceptances where needed.
  • For third-party facilities, obtain documentation and record your review and follow-ups.
  • Convert the whole control into a recurring evidence calendar (owner, artifact type, due dates) so audit readiness is continuous.

Frequently Asked Questions

Does Annex A 7.5 require specific technology like leak detection or a generator?

No specific technology is mandated in the provided control expectation. You need safeguards appropriate to your environmental risks and evidence that they operate. (ISO/IEC 27001 overview; ISMS.online Annex A control index)

We are fully cloud-hosted. Does 7.5 still apply?

Yes if you have offices, endpoints, network closets, or paper records that support information processing. For cloud providers’ facilities, treat them as third-party dependencies and retain proof of your due diligence and monitoring of that reliance. (ISO/IEC 27001 overview)

What evidence is most persuasive to an ISO auditor for this control?

Operational records beat policy statements: monitoring/alert configs, maintenance logs, test results, tickets from real environmental alerts, and documented exceptions with approvals. (ISO/IEC 27001 overview)

How do we handle colocation sites where the provider owns building systems?

Document what the provider is responsible for, obtain available facility/security documentation, and record your review and gap follow-up. If you cannot get certain artifacts, document compensating controls and the risk decision. (ISO/IEC 27001 overview)

Can we pass with only a policy and a risk register entry?

A policy and risk entry help with intent, but auditors typically expect evidence that controls exist and run (maintenance, tests, alerts, and remediation records). Build the control so it produces artifacts as a byproduct of operations. (ISO/IEC 27001 overview)

What’s the fastest “quick win” if we’re behind?

Start with a facilities register and a room-by-room walk-through, then fix obvious hazards (equipment on floors, blocked airflow, storage in comms rooms) and turn on monitoring with alert routing you can prove. (ISO/IEC 27001 overview)

Frequently Asked Questions

Does Annex A 7.5 require specific technology like leak detection or a generator?

No specific technology is mandated in the provided control expectation. You need safeguards appropriate to your environmental risks and evidence that they operate. (ISO/IEC 27001 overview; ISMS.online Annex A control index)

We are fully cloud-hosted. Does 7.5 still apply?

Yes if you have offices, endpoints, network closets, or paper records that support information processing. For cloud providers’ facilities, treat them as third-party dependencies and retain proof of your due diligence and monitoring of that reliance. (ISO/IEC 27001 overview)

What evidence is most persuasive to an ISO auditor for this control?

Operational records beat policy statements: monitoring/alert configs, maintenance logs, test results, tickets from real environmental alerts, and documented exceptions with approvals. (ISO/IEC 27001 overview)

How do we handle colocation sites where the provider owns building systems?

Document what the provider is responsible for, obtain available facility/security documentation, and record your review and gap follow-up. If you cannot get certain artifacts, document compensating controls and the risk decision. (ISO/IEC 27001 overview)

Can we pass with only a policy and a risk register entry?

A policy and risk entry help with intent, but auditors typically expect evidence that controls exist and run (maintenance, tests, alerts, and remediation records). Build the control so it produces artifacts as a byproduct of operations. (ISO/IEC 27001 overview)

What’s the fastest “quick win” if we’re behind?

Start with a facilities register and a room-by-room walk-through, then fix obvious hazards (equipment on floors, blocked airflow, storage in comms rooms) and turn on monitoring with alert routing you can prove. (ISO/IEC 27001 overview)

Operationalize this requirement

Map requirement text to controls, owners, evidence, and review workflows inside Daydream.